Quotations are hereby invited for the following: Transformer maintenance at SFF Milnerton. Scope of work: - Electrical contractor to do Major Service on our 12 x transformer. Transformer sizes are as follow: • 8 x 25kva = approximate litres = 168 litres; • 2 x 100 Kva = Approximate -322,7 litres; • 1 x 315Kva Approximate = 415 liters; • 1 x 300Kva = Approximate litres - 390 liters. Service include: • Test oil and provide oil report for each transformer, test must be done in accordance with transformer regulation. • Replace oil where oil do not meet the standard. • Refill Lower oil level with certified oil batch 3380532. • Check mechanical cooling system. • Check bushing of the transformer for cracks. • Replace gauge glass where necessary. • Replace breather oil where necessary. • Re-torque MV and LV bushing. • Apply Denso tape. • Clean transformer. • All label be done according to standard. Please confirm the contract number as two were published. (Offre №98340828fr)

S'inscrire

Partager:
Country: South Africa
Langue: EN
Nombre: 98340828
Date de publication: 24-01-2024
Source:

La description

Les informations complètes sur l'appel d'offres sont fermées.
Pour plus d'informations sur le site, lisez les informations ci-dessous.

À propos de nous

Premier moteur de recherche pour les appels d'offres et les achats en Russie et dans le monde

  • La plus grande base de données d'appels d'offres et de sources d'approvisionnement en Russie et dans le monde
  • Newsletter quotidienne gratuite selon vos paramètres
  • Informations sur les lauréats dans le format dont vous avez besoin
  • Affichage pratique et téléchargement d'informations

Choisissez-nous

Mise en route

Inscription sur le site, après quoi les fonctions du site suivantes sont à votre disposition:

  • Abonnez-vous à des listes de diffusion gratuites pour vos phrases clés
  • Afficher les annonces d'appels d'offres
  • Exporter les informations récapitulatives au format Excel
  • Voir une partie des informations sur les gagnants, fournisseurs et clients des appels d'offres

Enregistrement

Pour utiliser toutes les fonctions du site et afficher toutes les informations, vous devez créer un compte commercial

  • Tarif sélectionné
  • Payez l'accès de l'une des manières possibles

Accès total
Bids are hereby invited for the following: Supply and deliver consumables. Scope: - Refuse bags x 50 000; - Dust masks (20 in a box) x 100. Department: Zoo. Source: ONLINE TENDERS

Bids are hereby invited for the following: Supply and delivery of an automatic feeder paper shredder, Quantity: 01. Specifications: • Auto feed up to 600 sheets of A4 paper at a time; • P-4 cross cut; • 110L capacity bin; • Should have castor wheels for ease of movement; • Anti-jam technology; • Should be able to shred staples and paper clips; • Run time should be 240 min and should have a sleep mode; • Noise level: 55 DBA; • Should contain a bin full sensor. Source: ONLINE TENDERS

Bids are hereby invited for the following: Supply and delivery of an automatic feeder paper shredder, Quantity: 01. Specifications: • Auto feed up to 600 sheets of A4 paper at a time; • P-4 cross cut; • 110L capacity bin; • Should have castor wheels for ease of movement; • Anti-jam technology; • Should be able to shred staples and paper clips; • Run time should be 240 min and should have a sleep mode; • Noise level: 55 DBA; • Should contain a bin full sensor. Source: ONLINE TENDERS

Quotations are hereby invited for the following: Advance Excel and MS Projects Training at SFF Parow. Please note that this quotation was published late. Source: ONLINE TENDERS

Quotations are hereby invited for the following: Advance Excel and MS Projects Training at SFF Parow. Please note that this quotation was published late. Source: ONLINE TENDERS

Quotations are hereby invited for the following: Transformer maintenance at SFF Milnerton. Scope of work: - Electrical contractor to do Major Service on our 12 x transformer. Transformer sizes are as follow: • 8 x 25kva = approximate litres = 168 litres; • 2 x 100 Kva = Approximate -322,7 litres; • 1 x 315Kva Approximate = 415 liters; • 1 x 300Kva = Approximate litres - 390 liters. Service include: • Test oil and provide oil report for each transformer, test must be done in accordance with transformer regulation. • Replace oil where oil do not meet the standard. • Refill Lower oil level with certified oil batch 3380532. • Check mechanical cooling system. • Check bushing of the transformer for cracks. • Replace gauge glass where necessary. • Replace breather oil where necessary. • Re-torque MV and LV bushing. • Apply Denso tape. • Clean transformer. • All label be done according to standard. Please confirm the contract number as two were published. Source: ONLINE TENDERS